Both Wires Enter Same Side of insulated connector
Insulated Connector is 6061-T6 Aluminum CU9AL Dual Rated for use with Copper and/or Aluminum wires
Insulated with rugged high-dielectric rubber/vinyl coating
Pre-filled with oxide inhibitor
Easy re-entry for changes, inspection or troubleshooting
Plugs marked with connector max wire size for easy identification
Temperature range of –49°F to 194°F (–45° to 90°C)
ANSI C119.4 & cULus 486b Listed
Rated for use with 194°F(90°C) Cables
600 Volt
One wire per terminal
Indoor Use Only
No Cable Stripping or Crimping Required!
Insulation Piercing - Insulation Displacement Splicing Technology
Fully submersible, completely waterproof two port Insulation Piercing Connector AL9CU Dual Rated for Copper and Aluminum wire
Rubber Over-molded body ensures the Installer does not come into contact with bare metal conductor or the conductive material of the connector
Double shear-head bolt guarantees correct torque tightening every time, ensuring a quality connection, & eliminating the possibility of hot spots, damaged wires or loose connections
No cable stripping required, simply insert the jacketed cable into the entry port & tighten with a 1/2" 6 point socket
Order Qty of 1 = 1 Piece
Wire Connectors
Optional wire entry from either side
Dual Entry Insulated Connector is 6061-T6 Aluminum CU9AL Dual Rated for use with Copper and/or Aluminum wires
Insulated Connector has rugged high-dielectric Rubber/Vinyl Coating
Pre-Filled with Oxide Inhibitor
Easy Re-entry for Changes, Inspection or Troubleshooting
Plugs Marked with Connector Max Wire Size for easy identification
Temperature Range of –49°F to 194°F (–45° to 90°C)
ANSI C119.4 & cULus 486b Listed thru 750MCM
UL/CSA Certified through 750MCM size
Rated for use with 194°F(90°C) Cables
600 Volt
One wire per terminal
Indoor Use Only
No Cable Stripping or Crimping Required!
Insulation Piercing - Insulation Displacement Splicing Technology
Fully submersible, completely waterproof Multi-Port Insulation Piercing Connector AL9CU Dual Rated for Copper and Aluminum wire
Rubber Over-molded body ensures the Installer does not come into contact with bare metal conductor or the conductive material of the connector
Double shear-head bolt guarantees correct torque tightening every time, ensuring a quality connection, & eliminating the possibility of hot spots, damaged wires or loose connections
No cable stripping required, simply insert the jacketed cable into the entry port & tighten with a 1/2” 6 point socket
Order Qty of 1 = 1 Piece
Wire Range: (2) @ 2-350 & (4) @ 6-4/0
6061-T6 Aluminum CU9AL Dual Rated for use with Copper and/or Aluminum wires
Insulated Splice with rugged high-dielectric Rubber/Vinyl Coating
Pre-Filled with Oxide Inhibitor
Insulated Splice provides Easy Re-entry for changes, inspection or troubleshooting
Plugs marked with connector max wire size for easy identification
One wire per terminal
Temperature range of –49°F to 194°F (–45° to 90°C)
600 Volts
ANSI C119.4 & cULus 486b Listed
Rated for Use with 194°F(90°C) Cables
Indoor Use Only
Dimension Measurements = Inches
Order Qty of 1 = 1 Piece
Wires Enter the Same Side of the Connector
Insulated with rugged high-dielectric Rubber/Vinyl Coating
Pre-Filled with Oxide Inhibitor
Single Side Entry Cable Connector is 6061-T6 Aluminum CU9AL Dual Rated for use with Copper and/or Aluminum wires
Easy Re-Entry for Changes, Inspection or Troubleshooting
Plugs Marked with Connector Max Wire Size for easy identification
One wire per terminal
Temperature Range of –49°F to 194°F (–45° to 90°C)
ANSI C119.4 & cULus 486b Listed thru 750MCM
Rated for use with 194°F(90°C Cables)
600 Volt
Indoor Use Only
Dimension Measurements = Inches
Order Qty of 1 = 1 Piece
Set Screw Type:
4-14, 2-14 = Slotted Screw
1/0-14, 2/0-6, = 3/16” Allen Hex
3/0-6, 3/0-8, 3/0-10 = 1/4” Allen Hex
250-6, 350-6, 500-4, 600-250 = 5/16” Allen Hex
750-250 = 3/8” Allen Hex